- Steam traps
- Pressure regulators
- Control valves
-
- Control valves
- Two-way control valves
- Three-way control valves
- two-way on/off globe valves
- Intermittent blowdown valves & TDS blowdown control valves
- Pneumatic and electric linear actuators
- Universal controllers, transmitters, temperature sensors, digital panel, pneumatic and electric positioners
- Self-acting temperature control valves
- Two-way overflow valves
- Boiler house and special equipment
-
- Boiler house and special equipment
- Separators steam and compressed air
- Shell and tube & plate heat exchangers
- Sample coolers
- Direct steam injectors
- Flash vessels with inbuilt steam trap
- Blowdown expansion and cooling units in boiler houses
- Exhaust heads
- Hot condensate coolers
- Condensate lifting pots
- Steam-water mixers & Water-saving guns
- Level gauges & Magnetic level indicators
- Pressure operated pumps and packaged pump units
- Pipeline ancillaries
- Packaged units / Skids
- Clean steam equipment
-
- Clean steam equipment
- Clean Steam Generator
- Thermostatic clean steam traps
- Clean Service Control Valves
- Sanitary pressure regulators
- Clean Steam Separators
- Culinary steam filters
- Hygienic steam filters
- Clean Service Safety Valves
- Hygienic vacuum breakers
- Sample cooler clean steam
- Clean steam injectors
- Direct steam injection humidifiers
- Mushroom style air vent
- Three piece hygienic ball valves
- Three piece high purity ball valves
- Sanitary sight glass
- Sanitary pressure gauges
- Sanitary air vent valves
Control Panel Steam Boiler PRIMA-THERM
Specifications
Documentation
Applications: Maintaining the pressure, temperature and level of liquids in the deaeration system within a specified range. Communication connection: RS485, RS232, CAN bus, Ethernet.
Purpose of the automation panel: it is intended to maintain the parameters (pressure, temperature and level) within the range of set values. In this case, pressure control is carried out by adjusting the electric valves according to the algorithms stored in the PLC (programmable logic controller) memory. Depending on the system configuration, both pulse and analog control of pressure, temperature, and liquid level is possible.
Functions implemented by the automation panel in the basic configuration:
Maintaining the pressure, temperature, and level of liquids in the deaeration system within a specified range of values;
Controlling the power supply of the deaeration system (COD, condensate, etc.);
Functions for controlling the power supply of the deaeration system (COD, condensate, etc.).
Dispatching and remote control of the pumping station via RS485, RS232, CAN bus, Ethernet information interface.
DESCRIPTION BLOWDOWN CONTROLLER
Blowdown controller specially designed for use with steam boilers. The device takes care of both TDS and intermittent blowdown controls.
DS (Total Dissolved Solids) is controlled through measurement of the boiler water electrical conductivity and intermittent control is performed via a blowdown timer. The device utilizes a clear multifunction.
The device utilizes a clear multifunction LCD to display measured conductivity, temperature, operational alarm status and provide an intuitive user interface. The device is IP 66 rated NEMA 4X and can be panel, surface/wall and pipe mounted.
MAIN FEATURES BLOWDOWN CONTROLLER:
- TDS and intermittent blowdown control in one single device.
- Displays conductivity, resistivity, PPM and temperature units.
- Programmable cell constant.
- Розбірний герметичний корпус захищений за класом IP 66, NEMA 4X.
- Versatile IP 66 NEMA 4X (144 x 144 mm) enclosure design.
- Large informative 3,75’’ LCD backlit display.
- Simple intuitive menu structure with soft tactile function buttons.
- Software upgradable via SD card slot – Future proof.
- Volt-free outputs with multiple alarm function options.
- 0(4) to 20 mA analog output for remote monitoring purposes with features including adjustable scaling, selectable on-error states and loop fault detection.
- Digital input suitable for connection to the boiler stand-by/burner contact, to reduce energy waste.